Overview
EN ISO 22032:2009 (identical to ISO 22032:2006) specifies a validated laboratory method for the determination of selected polybrominated diphenyl ethers (PBDEs) in sediment and sewage sludge. The procedure uses solvent extraction, extract clean-up, and separation/detection by gas chromatography–mass spectrometry (GC‑MS). Detection modes covered are electron impact (EI) and negative ion chemical ionization (NCI). The standard defines scope, procedure, calibration and reporting requirements for reliable quantification of tetra‑ to octabromo congeners and decabromo diphenyl ether (BDE‑209).
Key topics and technical requirements
- Analytes covered: Selected PBDE congeners (see standard’s Table 1), including BDE‑47, BDE‑99, BDE‑100, BDE‑153, BDE‑154, BDE‑183 and BDE‑209.
- Sample prep principle: Drying, solvent extraction of PBDEs from sediment/sludge, followed by extract clean‑up (e.g., multi‑layer silica gel column) and concentration prior to GC‑MS analysis.
- GC‑MS modes:
- GC‑EI‑MS: Applicable concentration ranges approximately 0.05–25 µg/kg for tetra–octabromo congeners and 0.3–100 µg/kg for BDE‑209.
- GC‑NCI‑MS: Offers about ten‑times lower quantification limits (higher sensitivity) but different interference considerations.
- Calibration and quantification: Internal standard calibration over the whole procedure (use of isotopically labelled or suitable surrogate internal standards).
- Interferences and contamination controls: Potential co‑eluting compounds (e.g., BB‑153, tetrabromobisphenol A), naturally occurring brominated organics, and contamination from flame‑retarded polymers, airborne dust, vial caps, pipette fillers and recycled paper - the standard requires blank checks and contamination avoidance.
- Reagents and solvents: Examples include toluene, acetone, hexane, heptane, iso‑octane, nonane, dichloromethane; use anhydrous sodium sulfate and high‑purity gases (nitrogen for concentration/drying).
Practical applications
- Routine monitoring of PBDE contamination in river and lake sediments and in sewage sludge destined for disposal or land application.
- Environmental compliance testing for regulatory agencies and permitting.
- Research studies on PBDE distribution, fate and transport in aquatic environments.
- Contract testing by commercial environmental laboratories and consultants assessing pollutant loads or remediation effectiveness.
Who should use this standard
- Environmental and water quality laboratories performing POPs (persistent organic pollutants) analysis.
- Regulatory bodies and monitoring programs requiring standardized PBDE data.
- Academic researchers and consultants involved in sediment/sludge contaminant studies.
- QA/QC managers implementing validated GC‑MS methods for brominated flame retardants.
Related standards
- ISO 5667‑13 - Guidance on sampling of sludges from sewage and water‑treatment works.
- ISO 8466‑1 - Calibration and evaluation of analytical methods (statistical evaluation of linear calibration).
Keywords: EN ISO 22032, PBDE, BDE‑209, water quality, sediment analysis, sewage sludge, GC‑MS, electron impact, NCI, extraction, environmental monitoring.