ISO 1926:2009 - Rigid cellular plastics - Determination of tensile properties specifies a standardized method to measure how rigid cellular plastics behave under tensile stress. The standard defines specimen shapes, conditioning, test-machine requirements, test speed, data recording and calculation of tensile strength and elongation. It applies mainly to cellular materials with sufficient compression resistance to permit gripping; when gripping is not possible, the standard provides a variant using metal reinforcing plates.
Key topics and requirements
- Scope: Tensile testing procedure for rigid cellular plastics; variant for specimens that cannot be gripped (metal plates).
- Specimen shape and number: Test specimens follow the standard’s illustrated dimensions; at least five valid specimens are required. Specimens breaking outside the gauge length are rejected.
- Conditioning: Specimens must be conditioned per ISO 291. For precise measurement, a minimum of 6 hours at standardized atmospheres is specified (commonly 23 ± 2 °C and 50 ± 10 % RH).
- Test machine & clamps: Clamps must prevent slipping without introducing localized pressure damage. The movable grip rate is 5 ± 1 mm/min. Force measurement accuracy must be within ±1%.
- Extensometer: If used, it must exert minimal force and read gauge-length changes to 0.1 mm accuracy.
- Calculations: Tensile strength (kPa) is calculated from maximum force divided by the original cross-sectional area of the narrow section; elongation is expressed as percentage increase of original gauge length.
- Metal plate variant: Describes plate geometry, adhesive requirements (adhesive film shear strength greater than the material), and modified gripping arrangements when ends are reinforced.
- Precision: Interlaboratory data indicate typical repeatability ≈ 3% and reproducibility ≈ 10% for tensile measurements.
- Test report content: Must include reference to ISO 1926:2009, material description, conditioning, specimen type (note if metal plates used), number of specimens, orientation vs anisotropy, individual results and averages, stress–strain curve, deviations from the method and date.